Authors
Maximov B.I.
Moscow City Hospital №29 named after N.E.Bauman, Moscow
Abstract
This paper presents a clinical case of spontaneous extensor pollicis longus tendon rupture after volar locking plate fixation and consolidation of distal radius fracture and its successful surgical treatment.
Keywords: spontaneous rupture, extensor pollicis longus tendon, osteosynthesis, complication, distal radius.
References
1. Herron M, Faraj A, Craigen MA. Dorsal plating for displaced intra-articular fractures of the distal radius. Injury. 2003; 34(7): 497-502. doi:10.1016/s0020-1383(02)00190-0.
2. Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am. 2002; 27(2): 205-15. doi:10.1053/jhsu.2002.32081.
3. Yu YR, Makhni MC, Tabrizi S, Rozental TD, Mundanthanam G, Day CS. Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study. J Hand Surg Am. 2011; 36(7): 1135-41. doi:10.1016/j.jhsa.2011.04.004.
4. Asadollahi S, Keith PP. Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature. J Orthop Traumatol. 2013; 14(4): 227-234. doi: 10.1007/s10195-013-0245-z.
5. Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007; 21(5): 316-22. doi:10.1097/BOT.0b013e318059b993.
6. Azzi AJ, Aldekhayel S, Boehm KS, Zadeh T. Tendon rupture and tenosynovitis following internal fixation of distal radius fractures: a systematic review. Plastic and Reconstructive Surgery. 2017; 139(3): 717e-724e. doi: 10.1097/prs.0000000000003076.
7. Rhee PC, Dennison DG, Kakar S. Avoiding and treating perioperative complications of distal radius fractures. Hand Clin. 2012; 28(2): 185-98. doi:10.1016/j.hcl.2012.03.004.
8. Thorninger R, Madsen ML, Wæver D, Borris LC, Rölfing JHD. Complications of volar locking plating of distal radius fractures in 576 patients with 3.2 years follow-up. Injury. 2017; 48(6): 1104-1109. doi: 10.1016/ j.injury.2017.03.008.
9. Rellán I, Gallucci GL, Boretto JG, Donndorff A, De Carli P. Secondary tendinopathy after distal radius volar plate fixation: results of 8 years’ experience. Hand. 2016; 11(1): p. 38S. doi:10.1177/1558944716660555bd.
10. Duplay S. Rupture sous-cutanee du tendon du long extenseur du pouce de la main droite au niveau de la tabatire anatomique. Flexion permanente du pouce. Retablissement de la faculte d’extension par une operation (suture de I’extremite de tendon rompu avec Ie premier radial externe). Bull Mem Soc Chir Paris. 1876; 2: 788-791.
11. Sügün TS, Karabay N, Gürbüz Y, Özaksar K, Toros T, Kayalar M. Screw prominences related to palmar locking plating of distal radius. J Hand Surg Eur. 2011; 36E(4): 320-324. doi: 10.1177/1753193410392869.
12. Clement H, Pichler W, Nelson D, Hausleitner L, Tesch NP, Grechenig W. Morphometric analysis of lister’s tubercle and its consequences on volar plate fixation of distal radius fractures. J Hand Surg Am. 2008; 33(10): 1716-9. doi:10.1016/j.jhsa.2008.08.012.
13. Maksimov BI. Intraoperacionnaya ocenka dliny vintov pri nakostnom osteosinteze distal’nogo metaepifiza luchevoj kosti: kak izbezhat’ oshibki? Kafedra travmatologii i ortopedii. 2020; №1(39): S.30-38. (In Russ). doi:10.17238/issn2226-2016.2020.1.30-37.
14. Wall LB, Brodt MD, Silva MJ, Boyer MI, Calfee RP. The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates. J Hand Surg Am. 2012; 37(3): 446-53. doi:10.1016/ j.jhsa.2011.12.013.
15. Baumbach SF, Synek A, Traxler H, Mutschler W, Pahr D, Chevalier Y. The influence of distal screw length on the primary stability of volar plate osteosynthesis — a biomechanical study. J Orthop Surg Res. 2015; 10: 139. doi: 10.1186/s13018-015-0283-8.
16. Maschke SD, Evans PJ, Schub D, Drake R, Lawton JN. Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study. Hand (N Y). 2007; 2: 144-150. doi: 10.1007/s11552-007-9038-2.
17. Haug LC, Glodny B, Deml C, Lutz M, Attal R. A new radiological method to detect dorsally penetrating screws when using volar locking plates in distal radial fractures. The dorsal horizon view. Bone Joint J. 2013; 95-B(8):1101-5. doi:10.1302/0301-620X.95B8.31301.
18. Lemmen MH, Schreuders TA, Stam HJ, Hovius SE. Evaluation of restoration of extensor pollicis function by transfer of the extensor indicis. J Hand Surg Br. 1999; 24: 46-49.
19. Zheng X, An H, Chen T, Wang H. Effectiveness of modified extensor indicis proprius tendon transfer for reconstruction of spontaneously ruptured extensor pollicis longus tendon. Zhongguou Xiu Fu Chong Jian Wai Ke Za Zhi. 2012; 26(9): 1074-6.
20. Zhan H, Kan S, Fei Q. Evaluation of reconstruction of extensor pollicis function by transfer of extensor indicis. Zhongguou Xiu Fu Chong Jian Wai Ke Za Zhi. 2004; 18(4): 301-3.