DOI: 10.25881/BPNMSC.2018.90.19.030

Authors

Viller A.G., Khachaturov A.A., Stoyko Yu.M., Yashkin M.N., Bolomatov N.V., Marchak D.I., Litvinov A.A.

Federal State Budgetary Institution “National Medical and Surgical Center named after N.I. Pirogov” of the Ministry of Health of the Russian Federation

Abstract

More than 50 years in clinical practice for prevention of pulmonary embolism are used cava-filters of various modifications. After decrease in a risk level of pulmonary embolism there is a possibility of removal of the temporary cava-filter, however, in practice it not always probably. Experience of an original method of removal of the cava-filter is given in the present article from the cava vein, allowing to prevent the complications caused by the filter, instead of deep vein thrombosis. The developed original technique — single-lumen unilateral technique of cava-filter removing allows to reduce injury of intervention due to unilateral access, does possible removal of the filtering device even at his deviation from the central axis of the vein cava.

Keywords: deep vein thrombosis, pulmonary embolism, removing of cava-filter.

For citation

Viller A.G., Khachaturov A.A., Stoyko Yu.M., Yashkin M.N., Bolomatov N.V., Marchak D.I., Litvinov A.A. Single-lumen unilateral technique of cava-filter removing. Bulletin of Pirogov National Medical & Surgical Center. 2018;13(3):141-143. (In Russ.) https://doi.org/10.25881/BPNMSC.2018.90.19.030